Generators for Sale: 20 kW to 200 kW

Industrial-grade diesel, natural gas and LPG generators with Cummins, Perkins, Volvo, Kubota and Yangdong engines, sold and installed by Eaton Power & Equipment in Port St. Lucie, Florida.

Each model is a complete generator set (engine, alternator, controller and silent weather-proof enclosure) with its price, full specifications and a downloadable spec sheet on its product page. Single-phase units from 20 to 50 kW cover homes and small businesses. Three-phase Volvo units from 80 to 200 kW are built for commercial and industrial buildings. Not sure which fits? Use the sizing guide below or ask our team.

All generators

20 kW Perkins Diesel Generator

60 Hz EPA Perkins diesel generator, single-phase 110/220V, silent type

20 KW Single Phase 110/220V

25 kW Yangdong Diesel Generator

*Export Only. 60 Hz Yangdong diesel generator, 220V single-phase, silent type with built-in plugs

25 KW Single Phase 220V

30 kW Cummins Diesel Generator

60 Hz Cummins diesel generator, 220V single-phase, silent type with built-in plugs

30 KW Single Phase 220V

40 kW Kubota Diesel Generator

60 Hz Kubota diesel generator, 220V single-phase, silent type with built-in ATS and plugs, EPA Certificated Tier 4 Level

40 KW Single Phase 220V

50 kW Cummins Natural Gas Generator

Cummins natural gas generator, 50 kW prime / 55 kW standby, silent type, voltage configured to order

50 KW Natural Gas Voltage to Order

50 kW Cummins LPG Generator

Cummins liquefied petroleum gas generator, 50 kW prime / 55 kW standby, 220V single-phase, silent type

50 KW Single Phase 220V

80 kW Volvo Diesel Generator

60 Hz Volvo silent-type diesel generator, 480/277V three-phase, 240/127V three-phase and 220/110V single-phase

80 KW 3-Phase 480/277V

112 kW Volvo Diesel Generator

60 Hz Volvo silent-type diesel generator, 480/277V three-phase, 240/127V three-phase and 220/110V single-phase

112 KW 3-Phase 480/277V

200 kW Volvo Diesel Generator

60 Hz Volvo silent-type diesel generator, 480V three-phase with selectable 480/277V, 240/127V and 220/110V

200 KW 3-Phase 480V

Sizing Guide

How to Choose the Right Generator Size

Start with what has to run at the same time, then match the generator’s output to your electrical service. The table shows where each model typically fits. Your actual loads decide the final choice.

Generator sizing guide by power range
Power Output Typical applications Models
20–25 kW OutputSingle-phase 110/220V or 220V Typical applicationsHomes and small shops: essential circuits or a whole home, depending on loads Models20 kW Perkins Diesel
25 kW Yangdong Diesel (export only)
30–40 kW OutputSingle-phase 220V Typical applicationsLarger homes, farms and small commercial spaces with several motor loads Models30 kW Cummins Diesel
40 kW Kubota Diesel (built-in ATS)
50 kW gas OutputSingle-phase 220V or built to order Typical applicationsCommercial and residential standby where natural gas or LPG is available Models50 kW Cummins Natural Gas
50 kW Cummins LPG
80–112 kW OutputThree-phase 480/277V (multi-voltage) Typical applicationsCommercial buildings, workshops and light industrial sites on three-phase service Models80 kW Volvo Diesel
112 kW Volvo Diesel
200 kW OutputThree-phase 480V, selectable voltages Typical applicationsLarger commercial and industrial facilities and multi-building sites Models200 kW Volvo Diesel

Five steps to size a generator

  1. List your loads. Add up the running watts of everything that must operate at the same time.
  2. Allow for starting surges. Motors in air conditioners, pumps and compressors briefly draw several times their running current.
  3. Compare against prime power. Use the prime rating for everyday planning and treat the standby rating as outage headroom.
  4. Match phase and voltage. Single-phase buildings need a single-phase unit. Three-phase service needs one of the Volvo models.
  5. Pick a fuel and runtime. Decide between diesel, natural gas and LPG, and how long the unit must run between refuels.

kW, kVA and power factor

Single-phase models in our lineup are rated at a power factor of 1.0, so kW and kVA are the same. The three-phase Volvo units are rated at 0.8 power factor: the 80 kW unit is 100 kVA, the 112 kW is 140 kVA and the 200 kW is 250 kVA.

Send us your load list or utility bills and we can do the math with you.

Fuel Types

Diesel vs. Natural Gas vs. LPG

Diesel

Fuel is stored on site in the generator’s base tank (50–520 liters depending on model).

  • Runs independently of gas utilities during storms and outages
  • Runtime set by tank size and refueling; stored fuel needs periodic upkeep
  • Widest range of sizes, from 20 kW single-phase to 200 kW three-phase

Models

Natural Gas

Fuel comes from the utility gas line, with nothing to store or refill.

  • Runtime limited by gas service rather than tank size
  • Needs a gas meter and piping sized for the generator (0.8–30 kPa supply for our 50 kW unit)
  • A good fit for commercial, multi-family and residential sites that already have gas

Models

LPG (Propane)

Fuel is stored on site in a propane tank and refilled by delivery.

  • Works where there is no natural gas service
  • Keeps in storage without the fuel upkeep diesel needs
  • Tank size determines runtime; plan it with your propane supplier

Models

FAQ

Generator Buying Questions

Prime power is the output a generator can supply continuously with a varying load. Standby power is a higher rating for emergency use during a utility outage. Plan your everyday load against the prime rating. Each product page lists both.

Yes. We are based in Port St. Lucie and serve South Florida, and we offer installation services throughout the USA.

Yes. We provide custom power systems for homes, businesses and industrial sites, including specialized capacity, configuration or features. Tell us what you need.

Need Help Choosing?

Our team will help you find the right generator for your power requirements.